Pyroelectric potential change tested with the thermocouple (thermal resistance) results in imbalance signal through electrical bridge of temperature transmitter. The signal transforms into D.C. 4~20mA signal after being amplified and is transmitted to working meter, then working meter shows relevant temperature value.
Thermocouple with Temperature Transmitter Measuring Range & Tolerance
| 
				 
 
					 Type  | 
			
				 
 Graduation 
  | 
			
				 
					 Tolerance Class 
  | 
		|||
| 
				 
  | 
			
				 
  | 
			
				 
 
					  | 
			
				 
 
					  | 
		||
| 
				 
  | 
			
				 
  | 
			
				 Tolerance Value  | 
			
				 
					Measuring Range   | 
			
				 Tolerance Value  | 
			
				 
					Measuring Range   | 
		
| 
				 
 WRNB  | 
			
				 
					 K  | 
			
				 
					  | 
			
				 
					-40   | 
			
				 
					  | 
			
				 
					-40   | 
		
| 
				 
  | 
			
				 
  | 
			
				 
					  | 
			
				 
					375   | 
			
				 
					  | 
			
				 
					333   | 
		
| 
				 
 WRMB  | 
			
				 
					 N  | 
			
				 
					  | 
			
				 
					-40   | 
			
				 
					  | 
			
				 
					-40   | 
		
| 
				 
  | 
			
				 
  | 
			
				 
					  | 
			
				 
					375   | 
			
				 
					  | 
			
				 
					333   | 
		
| 
				 
 WREB  | 
			
				 
					 E  | 
			
				 
					  | 
			
				 
					-40   | 
			
				 
					  | 
			
				 
					-40   | 
		
| 
				 
  | 
			
				 
  | 
			
				 
					  | 
			
				 
					375   | 
			
				 
					  | 
			
				 
					333   | 
		
| 
				 
 WRFB  | 
			
				 
					 J  | 
			
				 
					  | 
			
				 
					-40   | 
			
				 
					  | 
			
				 
					-40   | 
		
| 
				 
  | 
			
				 
  | 
			
				 
					  | 
			
				 
					375   | 
			
				 
					  | 
			
				 
					333   | 
		
| 
				 
 WRCB  | 
			
				 
					 T  | 
			
				 
					  | 
			
				 
					-40   | 
			
				 
					  | 
			
				 
					-40   | 
		
| 
				 
  | 
			
				 
  | 
			
				 
					  | 
			
				 
					125   | 
			
				 
					  | 
			
				 
					133   | 
		
 
	Thermocouple with Temperature Transmitter Notices in Type Selection
1)Type
2)Graduation
3)Accuracy of Thermocouple (Thermal Resistance)
4)Mounting & Fixing
5)Protection Tube Material
6)Length or Insert Length
Example: thermocouple with temperature transmitter, type K, thread M27 2 316L for protection tube, length 450mm, insert length 300mm,WRNB-220,Lx1=450x300mm,dIIBT4, 316L protection tube, thread M27x2
Contact: Tiankang Export Sales Department
Phone: +86-18226665885
Tel: +86-0550-7788337
Email: sales@chinathermocouple.com